System 1.5 · Epoxy self-levelling floors
Antistatic epoxy self-levelling floor, 2 mm
A conductive epoxy coating with an earthing circuit that dissipates static electricity.
- Thickness
- 2 mm
- Layers
- 5
- Total consumption
- ≈ 4.4–4.6 kg/m²
- Service range
- −20 to +60 °C

Colour RAL 7040
The cutaway is redrawn right in your browser.
This gloss is not in the album: TNP's technical team will choose the layers for it.
Build-up
Layer by layer
The drawing is schematic; layer thicknesses are not to scale. Point at a layer to find it in the drawing; product names lead to their cards.
- 1 PrimingTeping R 1155 Primer 100Primer consumption depends on how absorbent the substrate is. 0.2–0.4
- 2 Scratch coatTeping Floor 205 Filler 1
- 3 Conductive layerCopper tape (earthing circuit) per design
- 4 Conductive layerTeping R 1155 Primer AS 0.22
- 5 TopcoatTeping Floor 205 AS 3
- Total≈ 4.4–4.6 kg/m²
Indicative estimate from the album consumption figures. Our technologist will confirm exact quantities for your substrate, with a margin.
Where it is used
- Laboratories
- Server rooms
- Oil production
- X-ray rooms
- Areas with explosion risk
- Switchboard rooms
Site types
Advantages
- Dissipates static through the earthing circuit
- Suits electronics rooms and areas with explosion risk
- Smooth gloss grey surface
Service conditions
- Mechanical load
- Moderate to significant: foot traffic, trolleys and forklifts on rubber tyres
- Liquids and chemicals
- Water, fuels and oils, weak solutions of salts, acids and alkalis
- Service temperature
- −20 to +60 °C
- Appearance
- Gloss, smooth; grey
Substrate requirements
- Moisture: max 4%
- Concrete age: at least 28 days
- Compressive strength: at least 20 MPa
- Pull-off strength: at least 1.5 MPa
- The substrate must be sound, uniform, clean and dry, free of laitance, oil, grease and old coatings.
Products
Products in this system
Every product in the system is made by TNP Group under the Teping® brand.
On site
Where a similar system already works
TNP Group sites finished with a close build-up of layers.
Epoxy floorsConfectionery plant: antistatic floor
Chudovo, Russia3,500 m²Teping Floor 205 AS
View project
Epoxy floorsAbrasives plant
Saint Petersburg, Russia1,538 m²Teping Floor 205 AS
View project
Epoxy floorsInstrument plant
Oryol, Russia1,000 m²Teping Floor 205 AS
View project
Epoxy floorsSwitchgear room
Moscow, Russia200 m²Teping Floor 205 AS
View project
Epoxy floorsWarehouse with antistatic floor
Saint Petersburg, Russia200 m²Teping Floor 205 AS
View project We will calculate the system for your site