Industrial floor · Cement
Teping Cem 60
High-strength wear-resistant floor
Cement mix with polymer fibre and granite aggregate for finished concrete floors 20–100 mm thick in workshops, warehouses, car parks and retail halls. The surface can be ground to terrazzo or used to level the base for a resin coating.
- Layer thickness
- 20 – 100 mm
- Compressive strength (28 days)
- ≥ 70 MPa
- Walk-on after
- 24 h
- Frost resistance
- F400

Overview
The product at a glance
Key points
- Compressive strength ≥ 70 MPa
- Abrasion resistant, F400, W16
- Can be ground to terrazzo
Where it is used
Facilities
- Manufacturing
- Warehouses
- Car parks, garages
- Shopping centres
- Sports facilities
Purpose
- Workshops, warehouses and plant rooms
- Car parks, retail halls and sports facilities
- Decorative terrazzo floors indoors and outdoors
- Levelling the base before resin topcoats; underfloor heating
Specifications
Technical data
Data from the TNP technical data sheet. Check the application instructions before design.
- Layer thickness
- 20 – 100 mm
- Compressive strength (28 days)
- ≥ 70 MPa
- Flexural strength (28 days)
- ≥ 10 MPa
- Bond to concrete
- ≥ 0.8 MPa
- Frost resistance
- F400
- Water impermeability
- W16
- Abrasion
- ≤ 0.4 g/cm²
- Fire hazard class
- Non-combustible (NG)
- Working time
- ≤ 40 min
- Walk-on after
- 24 h
- Service temperature
- −50 … +70 °C
- Consumption
- 1150 – 1200 kg of mix and 1150 – 1200 kg of aggregate per 1 m³
Quantity for your project
Consumption 1.15–1.2 kg/m² per 1 mm of thickness. An estimate from the consumption in the technical data sheet, without allowance for the substrate or losses. A TNP technologist will calculate the exact quantity.
Which thickness to choose
- 20 – 100 mm
- Finished floor for workshops, warehouses and car parks
- from 30 mm
- When finished with a power trowel
Installation
How it is applied
- 1Surface preparationThe substrate must be sound and dry (moisture up to 5 %), free of dust, oil and laitance; concrete at least 1–3 months old, screed at least 28 days.
- 2PrimingAn absorbent substrate is primed in two coats 2–3 hours apart; a non-absorbent one is milled or given a bonding primer. The mix is laid once the primer has fully dried.
- 3Preparing the mixPour 4–5 l of water per kit into a concrete mixer, add 25 kg of mix and 25 kg of granite aggregate, mix, then mix again after 3 minutes.
- 4ApplicationLay in strips between screed rails, level with a straightedge or vibrating screed and trowel once initial strength is reached. Protect from drying out for the first 3 days.
- 5Anchor groovesRepeat the substrate joints in the floor; without joints, cut bays of up to 6 × 6 m after 24–48 hours and fill them with polyurethane sealant after 7–10 days.
Packaging and delivery
- Dry mix
- 25 kg
- Granite aggregate 5–10 mm
- 25 kg
Product documents
Sent with the reply from a TNP technologist. Say in your enquiry which documents you need.

Your expert
Alexandra Antoshko
Head of Sales · Dry floor mixes
Helps you choose a coating, sends the TDS and works out quantities. Write in whichever of these languages suits you.
Let us match a solution to your project
Tell us the area, substrate and service conditions. A TNP technologist will suggest a system and calculate quantities and delivery times.